The existing water treatment plant was supplied in 1970. An upgrade of the water treatment plant was required, but no free space at site was available. Also, the construction works on-site was requested to be minimized.

It was decided to order the equipment built inside 40’ containers. Site installation was reduced to the pipe system and the electrical wiring between the containers.

Číslo reference: 022200
Industry: Teplárny a elektrárny
Application: Kotelní voda | Mobilní zařízení na úpravu vody

 

Vytvořit PDF

Technická data

  • Flow: 2 x 60 m³/h
  • Conductivity: <0.2 μS/cm
  • Silica SiO2: <0.02 mg/L
  • pH: ~ 8
  • Hardness: 1.5 °dH
  • Sodium Na+ and potassium K+ : 25 mg/L
  • Alcalinity: 10 mg/L
  • Chloride Cl- : 40 mg/L
  • Sulphate SO42-: 20 mg/L
  • Silica SiO2: 2 mg/l
  • KMnO4 -number: <3 mg/l

Jednotky v zařízení

  • Raw water pump 90 m³/h
  • Filtration 3 x TFB 20 PPA coated
  • Equipment for backwash
  • Cartridge filtration
  • Antiscalant dosing
  • Reverse osmosis unit C6-54
  • Cleaning unit
  • Electrodeionisation unit EDI 18-3400e
  • Pipe system in welded PP (polypropylene)

 